Kohler — Choke Adjustment
For these Kohler models: 7.5A27, 7.5R23.
Applies to: Kohler 7.5A27, Kohler 7.5R23
Procedure
- Loosen three screws on outside of cover plate.
- Shift cover in clockwise direction for richer setting or in counterclockwise direction for leaner setting.
- Tighten cover screws after final adjustment.
Specs & torque values
- Choke setting: average conditions at factory
Source: manual:TP5043 Kohler Gen Service 7.5R27 7.5A27 7.5A23 Marine (08-1987).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.