Kohler — Change Oil (Crankcase Plug)
Maintenance · Lubrication System
From a Kohler service manual covering: 1P14 690 11, XTX650, XTX675, XTX775. Check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- Disconnect and ground spark plug lead(s) before servicing
Procedure
- Disable engine by disconnecting spark plug.
- Clean area around oil fill cap/dipstick. Remove oil fill cap/dipstick.
- Remove crankcase plug on bottom of engine; drain oil into appropriate container.
- Apply thread sealant around three full threads of drain plug; reinstall drain plug.
- Torque drain plug to 13.6 N·m (120 in. lb.).
- Fill crankcase with new oil to top of indicator on dipstick.
- Reinstall oil fill cap/dipstick and tighten securely.
- Dispose of used oil in accordance with local ordinances.
Specs & values
- Drain plug torque 13.6 N·m (120 in. lb.)
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.