Home›Repair guides›Kohler›Float Switch Removal

Kohler CH5 / CH6 — Float Switch Removal

Repair & overhaul · Oil Sentry float switch

For the Kohler CH5 / CH6, from the Kohler service manual.

Applies to: Kohler CH6

Before you start

  • To prevent damage, remove switch by hand as soon as loose enough.
  • Do not pause rotation with N.C./N.O. markings in positions that cause float to strike oil pan.

Procedure

  1. Make sure engine/equipment is on level surface.
  2. Remove oil drain plug and drain oil.
  3. Disconnect float switch leads.
  4. Using 9/16 inch open end wrench, turn switch counterclockwise 1/4 turn to loosen. Stop when flat surface is horizontal.
  5. Turn switch counterclockwise in 1/2 turn increments using smooth continuous action. Pause briefly between increments.
  6. Remove switch by hand as soon as it is loose enough.

Tools required

  • 9/16 inch open end wrench Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Oil Sentry float switch torque: 13.6 Nm (120 in. lb.)

Full service-parts list: Kohler CH6 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.