Kohler CH5 / CH6 — Float Switch (Oil Sentry) Installation

Maintenance · Oil Sentry oil level monitor

For the Kohler CH5 / CH6, from the Kohler service manual.

Applies to: Kohler CH6

Before you start

  • Install switch by hand as long as it is loose enough

Procedure

  1. Drain oil from crankcase.
  2. Apply Loctite No. 592 Teflon sealant to entire thread area of switch.
  3. Apply thick film of clean SAE 30 oil to float and switch body.
  4. Insert switch with flat surface vertical (N.C./N.O. marking left) and turn 1/4 turn until flat surface horizontal.
  5. Turn switch clockwise in 1/2 turn increments with smooth continuous action.
  6. Turn switch about 5 to 6 full turns; tighten with 9/16 in. open end wrench with N.C. markings at top.

Tools required

  • 9/16 in. open end wrench Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Float switch torque 13.6 N·m (120 in. lb.)

Full service-parts list: Kohler CH6 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.