Home›Repair guides›Kohler›Bleeding Hydraulic Lifters

Kohler — Bleeding Hydraulic Lifters

Repair & overhaul · Cylinder Head

From a Kohler service manual covering: CV17, CV18, CV20, CV22, CV23, CV25, CV620, CV621, CV630, CV640, CV641, CV670…. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • To prevent a possible bent push rod or broken rocker arm, it is important to bleed any excess oil out of lifters before they are installed.

Procedure

  1. Cut a 50-75 mm (2-3 in.) piece from end of an old push rod and chuck it in a drill press.
  2. Lay a rag or shop towel on table of drill press and place lifter, open end up, on towel.
  3. Lower chucked push rod until it contacts plunger in lifter.
  4. Slowly pump plunger 2 or 3 times to force oil out of feed hole in side of lifter.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.