Kohler — AIR INTAKE SYSTEM
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- the breather hose, and if it is fabri¬
Procedure
- Remove wing nuts, air cleaner cover, element cover seals, element cover, and element (with precleaner).
- Remove the breather hose, air intake tube, and air cleaner cover seal from air cleaner base.
- Remove the screw securing air cleaner base to intake manifold. Lift base from intake elbow. Assembly
- Install air cleaner base and new base gasket on elbow and secure to intake manifold with hex head screw.
- Pull end of breather tube through 9/16” hole in base making sure lips on end of tube seal securely around hole in base.
- Slide air intake tube through hole in base so that end of tube extends into the blower hous¬ ing. The angled end of tube should face to the right (long side-left, short side-right) when inserted into the blower housing (as seen from the flywheel end). Make sure lips on end of tube seal securely around hole in base.
- Place element on base. 4a. Elements with precleaners have a cover which fits on top of the element. Place seals on studs extending through top of cover.
- Install air cleaner cover seal on base. Place cover on base and secure with two wing nuts— finger tightened 1/2 to 1 full turn after nuts contact cover—do not overtighten. (Seal on base must be in place and cover tightened to prevent vibration.) SECTION 3