Kohler — Service Paper Element (CH6)
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- 1. Remove the air cleaner cover. (See Service Precleaner, Step 1.)
- 2. Remove the precleaner from the air cleaner element.
- 3. Remove the air cleaner cover ring, element cover w/grommet, washer and wing nut. Pull the element cover w/grommet off. Remove paper element
- 4. Replace a dirty, bent, or damaged element with a genuine Kohler element. Do not wash the paper element or use pressurized air, as this will damage the element. Handle new elements carefully; do not use if the sealing surfaces are bent or damaged.
- 5. Install new or serviced paper element and components as follows: a. Position paper element on base. b. Slide element cover w/grommet then washer onto stud, secure with wing nut.
- 6. Reinstall the precleaner over the paper element.
- 7. Reinstall air cleaner cover ring into element cover. e. Reinstall air cleaner cover and secure with the retaining knob.
Specs & torque values
- 100 hours operation interval
- genuine Kohler element required
Source: manual:tp_2337_a.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.