Procedure
- 1. Remove the air cleaner cover. See Service Precleaner, Step 1.
- 2. Remove the precleaner from the air cleaner element retainer.
- 3. Remove the element retainer and paper element from the air cleaner base. See Service Paper Element, Step 3.
- 4. Remove the two air cleaner base mounting screws and the two air cleaner base mounting nuts.
- 5. Disconnect the breather tube from the air cleaner base, and remove the air cleaner base and gasket.