Kohler — Adjust Valve Tappet Clearance

Adjustments · Cylinder Head

From a Kohler service manual covering: SH255, SH265, SH270. Check it applies to your exact model before use.

Applies to: Kohler SH255

Procedure

  1. Be sure piston is still at top of compression stroke.
  2. Insert a flat feeler gauge between rocker arm and valve stem. Recommended clearance: intake 0.1 mm (0.0040 in.), exhaust 0.15 mm (0.0060 in.).
  3. Adjust clearance by loosening locknut and tightening adjuster. Turn clockwise to decrease clearance, counterclockwise to increase.
  4. Hold adjuster from turning and tighten locknut. Torque locknut to 10 N·m (88.5 in. lb.).
  5. Recheck that clearance is correct.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Intake 0.1 mm (0.0040 in.)
  • Exhaust 0.15 mm (0.0060 in.)
  • Locknut 10 N·m (88.5 in. lb.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.