Kohler — Adjust Valve Tappet Clearance
Adjustments · Cylinder Head
From a Kohler service manual covering: SH255, SH265, SH270. Check it applies to your exact model before use.
Applies to: Kohler SH255
Procedure
- Be sure piston is still at top of compression stroke.
- Insert a flat feeler gauge between rocker arm and valve stem. Recommended clearance: intake 0.1 mm (0.0040 in.), exhaust 0.15 mm (0.0060 in.).
- Adjust clearance by loosening locknut and tightening adjuster. Turn clockwise to decrease clearance, counterclockwise to increase.
- Hold adjuster from turning and tighten locknut. Torque locknut to 10 N·m (88.5 in. lb.).
- Recheck that clearance is correct.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Intake 0.1 mm (0.0040 in.)
- Exhaust 0.15 mm (0.0060 in.)
- Locknut 10 N·m (88.5 in. lb.)
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.