Kohler 48RCLB / 60RCLA — Procedure to Change the Exercise Setting
Operation · RDC2 controller exerciser
For the Kohler 48RCLB / 60RCLA, from the Kohler operator's manual.
Applies to: Kohler 48RCLB, Kohler 60RCLA
Before you start
- Use caution when navigating the controller menus; changing settings to incorrect values can adversely affect generator set operation or render the unit inoperable.
Procedure
- Press the AUTO button on the controller.
- Press the Select button to go to the main menu.
- Press the down arrow button to step to the Genset System menu.
- Press the Select button to enter the Genset System menu.
- Use the down arrow button to step to the next Exercise menu and press Select.
- Press the UP or Down arrow buttons to change the setting.
- Press the Select button to save the setting and move to the next.
- Repeat steps 5 through 8 to change the next item until the desired settings are displayed.
- Press Select to save after all settings have been selected; settings will stop flashing.
- If connected to a Model RXT transfer switch, set the Exercise Mode to loaded full speed, unloaded full speed, or unloaded cycle.
- Set the exercise frequency (weekly or every two weeks); weekly exercises are recommended.
- Press the down arrow button to step to the Return menu and press Select to return to the main menu.
- Check that the AUTO LED is lit.
Specs & values
- Exercise time 20 minutes
- Exercise frequency weekly or every other week
Full service-parts list: Kohler 48RCLB →, Kohler 60RCLA →
Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.