Installation

For the Kohler 48RCLB / 60RCLA, from the Kohler service manual.

Applies to: Kohler 48RCLB, Kohler 60RCLA

Before you start

  • Do not add coolant to a hot engine
  • Block heater will fail if not immersed in coolant

Procedure

  1. Close radiator drain valve and tighten hose clamps
  2. Remove enclosure cover plate to access coolant fill
  3. Fill radiator with recommended 50/50 coolant mixture; do not replace pressure cap yet
  4. Check oil level before operating engine
  5. Operate engine with pressure cap removed until thermostat opens and upper radiator hose becomes hot
  6. Stop engine and allow it to cool
  7. Add coolant to just below the overflow tube on the filler neck
  8. Replace the radiator pressure cap
  9. Maintain coolant level in overflow bottle between High and Low marks

Specs & values

  • Coolant mixture 50% ethylene glycol / 50% water

Full service-parts list: Kohler 48RCLB →, Kohler 60RCLA →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.