For the Kohler 48RCLB / 60RCLA, from the Kohler service manual.

Applies to: Kohler 48RCLB, Kohler 60RCLA, Kohler KG6208 engine

Before you start

  • Hot coolant and steam. Before removing the pressure cap, stop the generator set and allow it to cool. Then loosen the pressure cap to relieve pressure.

Procedure

  1. De-energize the block heater, if equipped.
  2. Remove the pressure cap to allow the entire system to drain and prevent air pockets.
  3. Open the coolant drain valve and allow the system to drain.
  4. If mineral deposits or dirt/grease are present, flush and clean (Section 4.7); otherwise refill (Section 4.8).

Full service-parts list: Kohler 48RCLB →, Kohler 60RCLA →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.