Home›Repair guides›Kohler›Breaker Point Gap Adjustment

Kohler 4.5 CKM — Breaker Point Gap Adjustment

Adjustments · Breaker points

For the Kohler 4.5 CKM, from the Kohler service manual.

Applies to: Kohler 4.5 CKM, Kohler KT17II engine

Before you start

  • Accidental starting can cause death or serious personal injury. Disconnect battery cables before working on generator.

Procedure

  1. Disconnect battery (negative lead first) and remove spark plug leads to prevent unintentional starting.
  2. Remove the breaker point cover.
  3. Remove the rotor end cap. With 3/4 in. socket wrench, rotate rotor bolt clockwise until points reach maximum opening.
  4. Measure the gap with a feeler gauge; gap at full open should be .017/.023 inch (.432/.580 mm).
  5. If not, loosen point gap adjustment screw; adjust by inserting screwdriver blade in adjusting notch and shifting movable plate.
  6. Securely tighten the adjusting screw after setting the gap.
  7. Replace the breaker point cover.
  8. Reconnect battery (negative lead last) and reconnect spark plug leads.
  9. Follow up with final or precision adjustment using a timing light.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • .017/.023 inch (.432/.580 mm)

Full service-parts list: Kohler 4.5 CKM →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.