Before you start

  • Perform storage procedure before removing generator set from service for three months or longer.

Procedure

  1. Operate generator set until operating temperature, about 15 minutes, then stop.
  2. While engine is still warm, drain lubrication oil from crankcase.
  3. Refill crankcase with oil, run a few minutes, and stop.
  4. Fuel system: start engine, shut off gas supply, run until engine stops.
  5. Place master switch in OFF/RESET position.
  6. Cylinder lubrication: remove spark plugs and pour one tablespoon of engine oil into each plug hole.
  7. Install spark plugs and ground the leads (do not connect to plugs).
  8. Toggle master switch to crank engine two or three revolutions.
  9. Clean exterior; seal engine openings with nonabsorbent tape.
  10. Mask electrical contact areas and apply light film of oil to unpainted surfaces.
  11. Battery last: place master switch in OFF/RESET, disconnect battery negative lead first.
  12. Clean battery and place in warm, dry location.
  13. Connect battery to float/equalize charger or charge monthly with trickle charger.

Specs & values

  • Engine oil: see Section 3.3.3 recommendations