Home›Repair guides›Kohler›Steps for common hardware application

Kohler 12RES — Steps for common hardware application

Installation · Fasteners

For the Kohler 12RES, from the Kohler service manual.

Applies to: Kohler 12RES

Procedure

  1. Determine entry hole type: round or slotted.
  2. Determine exit hole type: fixed female thread (weld nut), round, or slotted.
  3. For round and slotted exit holes, determine if hardware is greater than 1/2 inch in diameter or 1/2 inch or less.
  4. Follow the SAE washer rules after determining exit hole type, and refer to the hardware configuration figure.

Specs & values

  • Hardware greater than 1/2 inch in diameter takes a standard nut and SAE washer.
  • Hardware 1/2 inch or less in diameter can take a properly torqued whiz nut or spiralock nut.
  • Use split lock washers where specified; use SAE flat washers with whiz nuts, spiralock nuts, or standard nuts and preloading (torque) of the bolt in all other applications.

Full service-parts list: Kohler 12RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.