Home›Repair guides›Kohler›Mount the generator set

Kohler 12RES — Mount the generator set

Installation · Mounting base

For the Kohler 12RES, from the Kohler service manual.

Applies to: Kohler 12RES

Procedure

  1. Prepare concrete pad, 3000 PSI minimum.
  2. Use 3/8 inch anchor bolt and nut with 3/8 inch washer, typ 4 places.
  3. Set unit on plastic base over concrete pad.
  4. Verify bolted connection shear load 150 lbs/bolt and pull out force 200 lbs/bolt.
  5. For 150 mph high wind, use high wind mounting detail.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 3/8" anchor bolt & nut
  • 3/8" washer typ 4 places
  • Shear load 150 lbs/bolt
  • Pull out force 200 lbs/bolt
  • Concrete pad 3000 PSI min

Full service-parts list: Kohler 12RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.