Home›Repair guides›Kohler›Frequency Adjustment Procedure

Kohler 12RES — Frequency Adjustment Procedure

Adjustments · ADC controller / engine governor

For the Kohler 12RES, from the Kohler service manual.

Applies to: Kohler 12RES

Procedure

  1. Attach a frequency meter to the AC output leads or an electrical outlet on the load side.
  2. Start and run the generator set until it reaches normal operating temperature (at least 10 minutes).
  3. Adjust the electronic governor speed (parameter 4P) to obtain a frequency reading of 60 Hz (or 50 Hz).
  4. Check stability with the generator set running and no load applied; adjust governor stability (gain, parameter 5P) if unstable.
  5. Check the frequency reading and repeat prior steps if necessary.
  6. Save settings.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 60 Hz units operate at 3600 rpm; 50 Hz units run at 3000 rpm
  • Each step changes engine speed about 3.6 rpm, changing output frequency about 0.06 Hz

Full service-parts list: Kohler 12RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.