HomeRepair guidesChanging Custom Labels on RDP-110 Front Panel

Katolite — Changing Custom Labels on RDP-110 Front Panel

A Katolite service procedure — check it applies to your exact model before use.

Browse Katolite generators & specs →

Before you start

  • W
  • h
  • e
  • n
  • h
  • a
  • n
  • d
  • l
  • i
  • n
  • g
  • t
  • h
  • e
  • f
  • r
  • o
  • n
  • t
  • p
  • a
  • n
  • e
  • l
  • ,
  • a
  • v
  • o
  • i
  • d
  • t
  • o
  • u
  • c
  • h
  • i
  • n
  • g
  • t
  • h
  • e
  • c
  • i
  • r
  • c
  • u
  • i
  • t
  • b
  • o
  • a
  • r
  • d
  • .

Procedure

  1. Create the custom labels measuring 0.5 by 1.75 inches. Avery part number 18167 is suitable for this purpose.
  2. Remove all control power from the RDP-110.
  3. Remove the four Phillips screws from the front panel and separate the front panel from the conduit box. Disconnect the two connectors attached to the circuit board mounted to the front panel. When handling the front panel, avoid touching the circuit board.
  4. Lay the front panel face-down on a suitable work surface.
  5. Grasp the tab of the label card to be changed and pull free. The two label cards are located near the two lower corners of the circuit board. When facing the back of the panel, the pre-alarm label card is on the left and the alarm label card is on the right.
  6. Apply the labels created in step 1 to the label cards. The rectangle outlines on each label card serve as guides for attaching the labels.
  7. After applying the new labels, insert each label card into the appropriate panel slot. Ensure that each label card is oriented properly by viewing the custom labels through the label windows of the front panel.
  8. Move the panel assembly adjacent to the conduit box and reconnect the cables to the two circuit board connectors.
  9. Secure the front panel to the conduit box with the four Phillips screws removed in step 3. Maximum torque for these screws is 17 inch-pounds or 2 newton meters.
  10. If desired, verify the function of the reprogrammed indicators before returning the RDP-110 to service.

Specs & torque values

  • Avery label part number 18167
  • Label dimensions: 0.5 by 1.75 inches

Source: manual:RDP-110 Annunciator Manual_Revision F.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.