Home›Repair guides›Katolight›Stator Test

Katolight E6921M1 / REO2IMI — Stator Test

Testing & diagnosis · Alternator stator

For the Katolight E6921M1 / REO2IMI, from the Katolight service manual.

Browse Katolight generators & specs →

Procedure

  1. Measure all three line-to-line voltages at nameplate speed at no load.
  2. If all three voltages are almost identical and within nameplate rating, stator is operational.
  3. Otherwise see Resistance Checks, step D, 3.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Katolight service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.