Procedure
- Remove any drive arrangement from the generator shaft extension.
- Remove the bearing lock ring retaining screws.
- Support the shaft extension before proceeding further.
- Remove the bearing bracket retaining cap screws.
- Using a flat bladed screw driver or chisel, pry the bracket back from the frame.
- After approximately 1/8 inch, the bracket clears the locating register; lower the shaft extension until rotor rests on main stator core.
- Continue to pull the bracket free from the bearing.
- Visually inspect the bearing bore for damage or wear; sleeve or replace prior to reassembly.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Support capacity of 2 tons required
Source: Katolight service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.