Home›Repair guides›John Deere›Service Natural Gas Regulator

John Deere — Service Natural Gas Regulator

Maintenance · Fuel system

From a John Deere service manual — check it applies to your exact model before use.

Browse John Deere generators & specs →

Before you start

  • Natural gas is highly flammable. Shut off gas supply and relieve pressure before servicing.

Procedure

  1. Shut off natural gas supply and relieve internal regulator gas pressure.
  2. Unscrew union nut, be careful not to lose split rings.
  3. Disconnect balance tube from fitting.
  4. Remove four lower cap screws and remove regulator from support plate.
  5. Inspect and replace seat ring in union body if necessary.
  6. Remove cotter pin and replace disc holder assembly.
  7. Remove closing cap and turn adjusting screw counterclockwise until all spring compression is removed.
  8. Remove remaining cap screws and separate spring case from diaphragm case.
  9. Remove diaphragm assembly.
  10. Install new diaphragm assembly and tighten cap screw to 5 N·m (4 lb-ft).
  11. Install spring case and control spring.
  12. Tighten cap screws and hex nuts to 8 N·m (6 lb-ft) using a crisscross pattern.
  13. Install closing cap using a new gasket.
  14. Adjust regulator to desired outlet pressure setting.

Specs & values

  • Pusher post cap screw 5 N·m (4 lb-ft)
  • Spring case-to-diaphragm case 8 N·m (6 lb-ft)
  • Seat ring 47 N·m (35 lb-ft)

Source: John Deere service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.