Procedure

  1. Lubricate seal cavity in mounting flange with WD-40, LPS or equivalent.
  2. Install the stationary portion of the mechanical seal by sliding over the shaft with the ceramic side out.
  3. To seat the Seal in the seal cavity, use a piece of 3/4" PVC pipe 4" to 6" long; press the Seal in firmly and squarely.
  4. Install the rotary portion of the mechanical seal over the shaft with the carbon side facing in and press until it bottoms out.
  5. Insert the Key into shaft key slot, place Impeller on the Shaft, put Impeller Nut on shaft end and tighten securely.
  6. Install O-ring on Mounting Flange; place Pump Casing on the Mounting Flange and tighten the bolts alternately and evenly.