Before you start

  • If engine does not start after 20 seconds of cranking, pump hand primer an additional 50 strokes, wait at least 1 minute to let starter cool down, then attempt to start again.

Procedure

  1. Connect clear hose or pump with clear hose to diagnostic port; pump 0.5—1.0 gallons of fuel into a bucket using hand primer or an electric fuel pump.
  2. Remove clear hose/pump from diagnostic port.
  3. Remove fuel return line and cap off hose end and hose fitting.
  4. Pump hand primer 50 times to build fuel pressure in fuel rail.
  5. Start engine and run up to high idle for 1 minute.
  6. Repeat Step 5 until engine has started, allowing 2-3 minutes between cranking to cool starter.
  7. Holding return line over a bucket, remove cap and install into filter housing.
  8. Start engine and run up to high idle for 2 minutes, then stop engine.
  9. Ignition ON, engine OFF; clear any stored Diagnostic Trouble Codes (DTCs).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: John Deere service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.