Home›Repair guides›John Deere›Replacing Radial Seal Air Cleaner Filter Element

John Deere — Replacing Radial Seal Air Cleaner Filter Element

Maintenance

From a John Deere owner's manual covering: 4045TF120, 6068HF158, 6068TF120, 6068TF250. Check it applies to your exact model before use.

Applies to: John Deere 4045TF120, John Deere 6068TF120, John Deere 6068TF250

Before you start

  • Remove secondary (safety) element ONLY for replacement. DO NOT clean, wash, or reuse it.
  • Do NOT use latches on cover to force filter into air cleaner.

Procedure

  1. Unlatch and remove dust cup/cover of air cleaner.
  2. Move end of filter back and forth gently to break seal.
  3. Pull filter off outlet tube and out of housing.
  4. Thoroughly clean all dirt from inside housing and from outlet bore.
  5. To replace secondary element, pull filter element out gently. Immediately replace with new element.
  6. Install new primary filter element. Apply pressure by hand at outer rim of filter.
  7. Close housing with dust unloader valve aimed down and latch latches.
  8. Fully depress air restriction indicator reset button and release to reset indicator.

Full service-parts list: John Deere 6068TF250 →

Source: John Deere owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.