Home›Repair guides›John Deere›Replacing Axial Seal Air Cleaner Filter Element

John Deere — Replacing Axial Seal Air Cleaner Filter Element

Maintenance

From a John Deere owner's manual covering: 4045TF120, 6068HF158, 6068TF120, 6068TF250. Check it applies to your exact model before use.

Applies to: John Deere 4045TF120, John Deere 6068TF120, John Deere 6068TF250

Before you start

  • Remove secondary (safety) element ONLY for replacement. DO NOT attempt to clean, wash, or reuse secondary element.

Procedure

  1. Remove wing nut and remove canister cover.
  2. Remove wing nut and remove primary element from canister.
  3. Thoroughly clean all dirt from inside canister. If equipped, squeeze dust unloader valve tip to release trapped dirt.
  4. To replace secondary element, remove retaining nut and secondary element. Immediately replace with new element.
  5. Install new primary element and tighten wing nut securely. Install cover and tighten retaining wing nut securely.
  6. Fully depress air restriction indicator reset button and release to reset indicator.

Full service-parts list: John Deere 6068TF250 →

Source: John Deere owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.