Home›Repair guides›John Deere›Remove and Install Suction Control Valve

John Deere — Remove and Install Suction Control Valve

Repair & overhaul · Suction Control Valve (SCV)

From a John Deere service manual — check it applies to your exact model before use.

Browse John Deere generators & specs →

Before you start

  • Avoid contamination to the fuel high pressure pump or the suction control valve; maintain a high level of cleanliness.

Procedure

  1. Thoroughly clean suction control valve area (solenoid connector, mounting area, surrounding surfaces).
  2. Disconnect the suction control valve wire connector; do not twist the connector.
  3. Loosen 2 retaining bolts with a 5 mm Allen hex tool; do not completely remove.
  4. Remove the valve from the pump body by hand, pulling straight out; do not twist or pry.
  5. Install a properly sized cap plug in the valve opening in the pump body.
  6. Remove and discard the 2 retaining bolts.
  7. Verify the overall reference length of the new valve to be 27.6 mm (1.09 in.).
  8. Confirm replacement parts in kit; lubricate O-rings with diesel fuel.
  9. Install large O-ring into groove in pump housing.
  10. Install new suction control valve into pump body by hand, pushing straight in.
  11. Install new retainer bolts; tighten evenly to 9 N•m (7 lb-ft).
  12. Connect suction control valve wire harness to electrical connector.
  13. Connect negative battery cable.
  14. Start engine, perform computer diagnostics, and check joint for fuel leaks.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Suction control valve reference length—27.6 mm (1.09 in.)
  • Suction Control Valve to Pump Housing—9 N•m (7 lb-ft)

Source: John Deere service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More John Deere repair guides →