Home›Repair guides›John Deere›Pump Housing Disassembly (All Models)

John Deere — Pump Housing Disassembly (All Models)

Repair & overhaul · Pump casing / impeller

From a John Deere service manual — check it applies to your exact model before use.

Browse John Deere generators & specs →

Before you start

  • Always flush pump with water or neutralizing agent before servicing.
  • O-ring should always be replaced.

Procedure

  1. Remove the four Casing Cap Screws with a 9/16" box end wrench; tap the Pump Casing on discharge port to break it loose.
  2. Check inside of Pump Casing including suction port; replace if badly eroded or damaged. Remove O-ring and discard.
  3. To remove the Impeller Nut, clamp the Flange in a vise and insert a large screwdriver or file into the Impeller Vanes.
  4. Use a socket wrench (3/4" for Series PM9000CO or 5/8" for Series PM9200C and PM9400C) to remove the Impeller Nut by turning counterclockwise.
  5. Once the Nut is removed, pry the Impeller away from the Mounting Flange using a screwdriver on each side.
  6. Remove Woodruff Key from the Shaft (Series PM9000CO only) and remove O-ring from the Mounting Flange.

Tools required

  • 9/16" box end wrench Amazon
  • large screwdriver or file (at least 10" [254 mm] long) Amazon
  • 3/4" socket wrench Amazon
  • 5/8" socket wrench Amazon
  • 7/8" deep socket wrench Amazon
  • 9/16" deep socket Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: John Deere service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More John Deere repair guides →