Home›Repair guides›John Deere›Flushing and Refilling Cooling System

John Deere 6068HF475 — Flushing and Refilling Cooling System

Maintenance

For the John Deere 6068HF475, from the John Deere owner's manual.

Applies to: PowerTech 6068HF475

Before you start

  • Do not run engine longer than 10 minutes with water.

Procedure

  1. Pressure test cooling system and cap if not done.
  2. Open filler/radiator cap slowly to relieve pressure.
  3. Open engine block drain valve/plug and radiator drain valve.
  4. Fill system with clean water; run engine about 10 minutes.
  5. Drain water; refill with water and heavy-duty cooling system cleaner.
  6. Drain cleaner; flush with water; close all drain valves.
  7. Install thermostats with new gasket; add coolant to bottom of filler neck.
  8. Run engine to operating temperature; check level and leaks.

Specs & values

  • 4.5 L coolant capacity 8.5 L (9 qt)
  • 6.8 L coolant capacity 11.3 L (12 qt)

Full service-parts list: PowerTech 6068HF475 →

Source: John Deere owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More John Deere repair guides →