Iveco/FPT — Removing and refitting the sound-proofing unit
Maintenance
From a Iveco/FPT service manual covering: GE NEF 100M, GE NEF 125M, GE NEF 130M, GE NEF 160M, GE NEF 200E, GE NEF 45M, GE NEF 60M, GE NEF 75M, GE NEF 85M, GS NEF 100M, GS NEF 125M, GS NEF 130M…. Check it applies to your exact model before use.
Applies to: Iveco/FPT GE NEF 100M, Iveco/FPT GE NEF 125M, Iveco/FPT GE NEF 130M, Iveco/FPT GE NEF 160M, Iveco/FPT GE NEF 200E, Iveco/FPT GE NEF 45M, Iveco/FPT GE NEF 60M, Iveco/FPT GE NEF 75M, Iveco/FPT GE NEF 85M, Iveco/FPT GS NEF 100M, Iveco/FPT GS NEF 125M, Iveco/FPT GS NEF 130M
Before you start
- When removing pipe pay attention not to damage cooling unit air ducts.
- Make sure rods have the same length to lift the soundproofing unit along the vertical axis.
Procedure
- Operate from control board side and disconnect electric connection from stop button.
- Move back exhaust pipe cover to reach stop collar, loosen fastening screw.
- Loosen covering panel fastening nuts from exhaust pipes side and remove panel.
- Remove pipe from its seat.
- Loosen soundproofing unit fastening screws along perimeter.
- Secure hooks with chain catches in slots and lift soundproofing unit with hoisting device.
Source: Iveco/FPT service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.