Home›Repair guides›Iveco/FPT›Passage from 50 Hz to 60 Hz (NEF motors with Stanadyne pump)

Iveco/FPT — Passage from 50 Hz to 60 Hz (NEF motors with Stanadyne pump)

Adjustments · Stanadyne injection pump

From a Iveco/FPT service manual covering: N45, N67, NEF45 SM2. Check it applies to your exact model before use.

Applies to: Iveco/FPT N45, Iveco/FPT N67, Iveco/FPT NEF45 SM2

Before you start

  • Do not force the droop setting screw beyond its final position to avoid damaging the adjustment system.

Procedure

  1. Identify the injection pump code from the Stanadyne tag.
  2. Act on the droop setting adjustment screw rotating it clockwise the number of rotations from the chart.
  3. Start the motor and loosen the maximum regime adjustment screw; accelerate to obtain 62 Hz (1860 rpm) no-load speed.
  4. Regulate the minimum regime screw to block the accelerator lever in the newly obtained position.
  5. Block both adjustment screws with lock nuts (3.5 ÷ 4 Nm).

Specs & values

  • Droop setting screw rotations from chart (e.g. DB 4429-5945: 3 turns from 50 Hz to 60 Hz)

Source: Iveco/FPT service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.