Iveco/FPT — Assembly procedure of the ADC100 electronic activator on Stanadyne series D injection pumps
Installation · Stanadyne injection pump
From a Iveco/FPT service manual covering: N45, N67, NEF45 SM2. Check it applies to your exact model before use.
Applies to: Iveco/FPT N45, Iveco/FPT N67, Iveco/FPT NEF45 SM2
Before you start
- Coupling mistakes between the actuator hook and the injection pump lever can cause motor over-speed conditions.
Procedure
- Remove the three screws of the pump cover and remove the cover carefully.
- Remove the connection of the fuel return pipe and the sealing from the cover.
- Disconnect the wire of the stop electro-valve from the clamp and isolate it.
- Reassemble the connection and the pump cover's original sealing on the ADC100 electronic actuator.
- Slide the actuator towards the rear of the pump until the U-shaped hook engages the pump lever.
- Tighten the ADC100 actuator to the injection pump using the supplied screws.
- Reconnect the fuel return pipe to the connection on the actuator.
Source: Iveco/FPT service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.