Home›Repair guides›Isuzu›Compressor Removal (6VD1/6VE1 LHD)

Isuzu — Compressor Removal (6VD1/6VE1 LHD)

Repair & overhaul · A/C compressor

From a Isuzu service manual — check it applies to your exact model before use.

Browse Isuzu generators & specs →

Before you start

  • O-rings cannot be reused; always replace with new ones and apply new compressor oil.

Procedure

  1. Disconnect battery ground cable.
  2. Discharge and recover refrigerant.
  3. Disconnect magnetic clutch harness connector.
  4. Move serpentine belt tensioner to loose side; remove serpentine belt.
  5. Disconnect refrigerant line connector; immediately plug or cap.
  6. Remove compressor.

Tools required

  • Wrench (belt tensioner) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Compressor fixing torque 19 N·m (1.9/14)
  • Refrigerant line bolt torque 15 N·m (1.5/11)

Source: Isuzu service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Isuzu repair guides →