Procedure
- Strip wire ends 1/4 inch.
- Re-twist any loose wire strands.
- Slide 2 inch pieces of heat shrink tube over wire for later use.
- Insert ends of wires into splice joint and crimp.
- Solder the wires and crimp joint together.
- Center heat shrink tube over splice and shrink.
- Wrap wires with electrical tape or heat shrink tubing. Maintain at least 1/2 wrap overlap.
- Once electrical tape or heat shrink tubing is in place, there should be no exposed wires.
Source: International service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.