Procedure
- 1. Assemble Muffler (31) and Screen (30) into Housing, securing with Retaining Ring (29).
- 2. For Models 41TS and 41TP, coat Valve Rod (27) with the recommended oil and install Valve Rod and Spring (26) in Housing.
- 3. Install Inlet Adapter (25) in tool.
- 4. Clean and replace Screen (1) in Inlet Adapter.
- 5. Coat Trigger (44) or Button (46) with the recommended oil and install in Reverse Cam (43).
- 6. For Models 41TS and 41TP, lubricate and install O-Ring (42) on Trigger (44).
- 7. Install Springs (41) on Reverse Cam, flat side away fromReverse Cam, and install Reverse Cam and components in Housing, aligning holes in
- Trigger and Housing.
- 8. Install Pin (40) in Housing, securing Reverse Cam and Trigger.
- 9. Install Bushing (48) in Housing, pressing flush with counterbore in bottom of motor cavity.
- 10. Install Roll Pin (47) in Housing, pressing flush with bottom of motor cavity.
- 11. Coat Reverse Valve (36) with the recommended oil and install in Housing, aligning slot in Reverse Valve with Roll Pin (47).
- 12. Install Spring (37) in Housing.
- 13. Lubricate and install O-Ring (38) in Top Cap (39) and install Cap in Housing, securing Spring (37) and Reverse Valve (36).
- 14. Coat Valve Rod (35) with the recommended oil and install in Housing.
- 15. Install Spring (34) in Housing, where applicable.
- 16. Lubricate and install O-Ring (33) in End Cap (32) and install Cap in Housing, securing Valve Rod and Spring.
- Assembly of the Motor
Source: manual:16575284_ed2_b.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.