Procedure

  1. 1. Assemble Muffler (31) and Screen (30) into Housing, securing with Retaining Ring (29).
  2. 2. For Models 41TS and 41TP, coat Valve Rod (27) with the recommended oil and install Valve Rod and Spring (26) in Housing.
  3. 3. Install Inlet Adapter (25) in tool.
  4. 4. Clean and replace Screen (1) in Inlet Adapter.
  5. 5. Coat Trigger (44) or Button (46) with the recommended oil and install in Reverse Cam (43).
  6. 6. For Models 41TS and 41TP, lubricate and install O-Ring (42) on Trigger (44).
  7. 7. Install Springs (41) on Reverse Cam, flat side away fromReverse Cam, and install Reverse Cam and components in Housing, aligning holes in
  8. Trigger and Housing.
  9. 8. Install Pin (40) in Housing, securing Reverse Cam and Trigger.
  10. 9. Install Bushing (48) in Housing, pressing flush with counterbore in bottom of motor cavity.
  11. 10. Install Roll Pin (47) in Housing, pressing flush with bottom of motor cavity.
  12. 11. Coat Reverse Valve (36) with the recommended oil and install in Housing, aligning slot in Reverse Valve with Roll Pin (47).
  13. 12. Install Spring (37) in Housing.
  14. 13. Lubricate and install O-Ring (38) in Top Cap (39) and install Cap in Housing, securing Spring (37) and Reverse Valve (36).
  15. 14. Coat Valve Rod (35) with the recommended oil and install in Housing.
  16. 15. Install Spring (34) in Housing, where applicable.
  17. 16. Lubricate and install O-Ring (33) in End Cap (32) and install Cap in Housing, securing Valve Rod and Spring.