Procedure
- 1. Remove End Cap (32) and O-Ring (33), releasing Spring (34) and Valve Rod (35).
- 2. Remove Top Cap (39) and O-Ring (38), releasing Spring (37) and Reverse Valve (36).
- NOTICE
- Do not remove Roll Pin (47) or Bushing (48) unless damage is evident.
- 3. To remove Roll Pin or Bushing, press thru to reverse valve cavity.
- 4. To remove Trigger (44) or Button (46), Drive Pin (40) out of Housing, releasing Trigger or Button, Reverse Cam (43) and Springs (41).
- 5. For Models 41TS and 41TP, remove O-Ring (42), releasing Trigger from Reverse Cam (43).
- 6. Remove Inlet Adapter (25) and Screen (1).
- 7. For Models 41TS and 41TP, remove Spring (26) and Valve Rod (27).
- 8. Remove Retaining Ring (29), releasing Screen (30) and Muffler (31).
- Assembly
- General Instructions