Ingersoll Rand — Pistol Grip Housing
A Ingersoll Rand service procedure — check it applies to your exact model before use.
Browse Ingersoll Rand generators & specs →
Procedure
- 1. Assemble Muffler (31) and Screen (30) into Housing, securing with Retaining Ring (29).
- 2. For Models 41TS and 41TP, coat Valve Rod (27) with the recommended oil and install Valve Rod and Spring (26) in Housing.
- 3. Install Inlet Adapter (25) in tool.
- 4. Clean and replace Screen (1) in Inlet Adapter.
- 5. Coat Trigger (44) or Button (46) with the recommended oil and install in Reverse Cam (43).
- 6. For Models 41TS and 41TP, lubricate and install O-Ring (42) on Trigger (44).
- 7. Install Springs (41) on Reverse Cam, flat side away fromReverse Cam, and install Reverse Cam and components in Housing, aligning holes in
Source: manual:16575284_ed2_b.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.