A Ingersoll Rand service procedure — check it applies to your exact model before use.

Browse Ingersoll Rand generators & specs →

Before you start

  • NOTICE

Procedure

  1. 1. Remove End Cap (32) and O-Ring (33), releasing Spring (34) and Valve Rod (35).
  2. 2. Remove Top Cap (39) and O-Ring (38), releasing Spring (37) and Reverse Valve (36).
  3. Do not remove Roll Pin (47) or Bushing (48) unless damage is evident.
  4. 3. To remove Roll Pin or Bushing, press thru to reverse valve cavity.
  5. 4. To remove Trigger (44) or Button (46), Drive Pin (40) out of Housing, releasing Trigger or Button, Reverse Cam (43) and Springs (41).
  6. 5. For Models 41TS and 41TP, remove O-Ring (42), releasing Trigger from Reverse Cam (43).
  7. 6. Remove Inlet Adapter (25) and Screen (1).
  8. 7. For Models 41TS and 41TP, remove Spring (26) and Valve Rod (27).
  9. 8. Remove Retaining Ring (29), releasing Screen (30) and Muffler (31).

Source: manual:16575284_ed2_b.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.