Ingersoll Rand — Lever Throttle
A Ingersoll Rand service procedure — check it applies to your exact model before use.
Browse Ingersoll Rand generators & specs →
Procedure
- 1. Secure Air Inlet Adapter (2) in a vise with leather-covered or copper-covered jaws.
- 2. Using a strap type wrench, unthread Housing (15).
- 3. Remove Spacer (3), Diffuser Washer (4), Exhaust Cap (5), Filler (6), Spring (7) and Valve Assembly (8).
- 4. Remove Cap (21) and Spring (19), releasing Valve Stem (18).
- 5. Remove Valve Block (10) and Spring (11), releasing valve Assembly (12).
- NOTICE
- Do not remove or adjust rubber portion of Valve Assemblies (8) and (12), as they are preset at the factory.
- 6. Remove O-Ring (13) and Reverse Sleeve (14), releasing Valve Body (17) and Spring (16).
- Pistol Grip Housing
Source: manual:16575284_ed2_b.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.