Ingersoll Rand — Disassembly of the Air Impactool
A Ingersoll Rand service procedure — check it applies to your exact model before use.
Browse Ingersoll Rand generators & specs →
Procedure
- Grasp tool in copper-covered or leather-covered vise jaws with square drive upward.
- Squeeze sides of the Exhaust Deflector (32) and remove from Motor Housing Assembly (26). Remove the Exhaust Silencer (33).
- Using a hex wrench, unscrew and remove the four Hammer Case Cap Screws (41) and remove Dead Handle Bracket (42).
- While lightly tapping on the end of Anvil (38) with a plastic hammer, lift off Hammer Case (39).
- Remove the Hammer Case Gasket (34).
- Remove Anvil by rotating it as it is lifted out of the assembly.
- Lift remaining hammer assembly off rotor shaft.
- Push two Hammer Pins (36) out of the Hammer Frame Assembly (35) and slide two Hammers (37) out of the Frame.
Tools required
- Hex wrench
- Plastic hammer
Specs & torque values
- Exhaust Deflector (32)
- Motor Housing Assembly (26)
- Exhaust Silencer (33)
- Hammer Case Cap Screws (41)
- Dead Handle Bracket (42)
- Hammer Case (39)
- Hammer Case Gasket (34)
- Anvil (38)
- Hammer Frame Assembly (35)
- Hammer Pins (36)
- Hammers (37)
Source: manual:10569408ed2b.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.