Procedure
- Clamp Trigger Handle Assembly in leather-covered or copper-covered vise jaws with the Straight Inlet (10) upward.
- Using a wrench, unscrew and remove Inlet as well as Air Strainer Screen (9) and valve Spring (8).
- Remove Throttle Valve Assembly (6) and Valve Plunger (5) from Handle.
- If Trigger (3) must be removed, use an arbor press to push Trigger Pin (4) from the Handle and slide Trigger out of slot in Handle.
Tools required
- Wrench
- Arbor press
Specs & torque values
- Trigger Handle Assembly
- Straight Inlet (10)
- Air Strainer Screen (9)
- Valve Spring (8)
- Throttle Valve Assembly (6)
- Valve Plunger (5)
- Trigger (3)
- Trigger Pin (4)