- 17. Splined hub removal:
- a.
- FA2 Winches: Remove splined hub (19) from shaft
- (35) followed by retainer ring (32).
- b.
- FA2.5 Winches: Loosen the capscrew in collar (18)
- and slide collar from shaft (35) with the splined hub
- (19). Remove retainer ring (32) and spacer (34)
- from shaft (35).
- 18. Remove retainer ring (36) from the bore of the drum
- shaft (41).
- 19. Pull shaft and bearing assembly from the drum shaft
- (41).
- 20. Support the drum (80) and remove capscrews (39) from
- the drum shaft (41). Pry drum shaft (41) from the inboard
Source: manual:Ingersoll-Rand-FA2-FA2.5-Parts-Operation-and-Maintenenace-Manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.