Procedure
- Rotate the regulator adjustment knob (145) counterclockwise until torque tube lowers to bottom of travel.
- Turn off the main supply to the torque tube.
- Disconnect main air supply from regulator at connector (142).
- Remove the torque tool from the torque tube.
- Disconnect air cylinder connecting clip (114) from attachment plate (117).
- Remove capscrews (107), nuts (123) and washers (108).
- Remove air cylinder (106).
- Remove inner shaft assembly (109-117).
- Remove capscrews (126), nuts (127) and washers (128).
- Remove inner support tube (100) from outer support tube (129).
Source: Ingersoll Rand service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.