Home›Repair guides›Ingersoll Rand›Disassembly of the Quick-Change Anvil

Ingersoll Rand — Disassembly of the Quick-Change Anvil

Repair & overhaul

From a Ingersoll Rand service manual — check it applies to your exact model before use.

Before you start

  • The Retaining Ball (47) will fall free once the Retaining Sleeve (43) is removed.

Procedure

  1. Clamp the handle of the tool in vise jaws with the Quick-Change Anvil (42) upward.
  2. Remove front Thrust Ring Lock (44) and Thrust Ring (45).
  3. Remove the Retaining Sleeve Spring (46), Retaining Sleeve, Retaining Ball, and the rear Thrust Ring Lock.
  4. Remove the four Backcap Bolts (14). While lightly tapping the Anvil with a plastic hammer, lift off the Hammer Case (39).
  5. Remove and discard the Hammer Case Gasket (37).
  6. Grasp the Hammer Frame (34) and lift off the impact mechanism, not dropping the two Hammer Pins (36).
  7. Remove the Rear Hammer Frame Washer (33).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Ingersoll Rand service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.