Ingersoll Rand — Air Cylinder Removal
Repair & overhaul
From a Ingersoll Rand service manual — check it applies to your exact model before use.
Procedure
- Rotate the regulator adjustment knob (145) counterclockwise until torque tube lowers to bottom of travel.
- Turn off the main supply to the torque tube.
- Disconnect main air supply from regulator at connector (142).
- Remove the torque tool from the torque tube.
- Disconnect air cylinder connecting clip (114) from attachment plate (117).
- Remove regulator (145) and hex nipple (36) from air cylinder (106).
- Remove air cylinder exhaust vent (105) from rod end of air cylinder (106).
- Remove air cylinder mount nut from rod end of air cylinder (106).
- Remove air cylinder from rod end mounting bracket (119).
- Remove air cylinder from cap end mounting bracket (120).
Source: Ingersoll Rand service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.