Home›Repair guides›Honda›Connecting the Battery Cables (DC Operation)

Honda EG1400X / EG2500 — Connecting the Battery Cables (DC Operation)

Operation · DC battery charging circuit

For the Honda EG1400X / EG2500, from the Honda owner's manual.

Applies to: Honda GX120K1 engine, Honda GX160K1 engine

Before you start

  • The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation.
  • Do not start the vehicle while the battery charging cables are connected and the generator is running.

Procedure

  1. Before connecting charging cables to a battery installed in a vehicle, disconnect the vehicle's grounded battery cable.
  2. Connect the positive (+) battery cable to the battery positive (+) terminal.
  3. Connect the other end of the positive (+) cable to the generator positive (+) terminal.
  4. Connect the negative (-) battery cable to the battery negative (-) terminal.
  5. Connect the other end of the negative (-) cable to the generator negative (-) terminal.
  6. Start the generator.

Specs & values

  • DC terminals may ONLY be used for charging 12 volt automotive-type batteries

Source: Honda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.