Honda EG1400X / EG2500 — Connecting the Battery Cables (DC Operation)
Operation · DC battery charging circuit
For the Honda EG1400X / EG2500, from the Honda owner's manual.
Applies to: Honda GX120K1 engine, Honda GX160K1 engine
Before you start
- The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation.
- Do not start the vehicle while the battery charging cables are connected and the generator is running.
Procedure
- Before connecting charging cables to a battery installed in a vehicle, disconnect the vehicle's grounded battery cable.
- Connect the positive (+) battery cable to the battery positive (+) terminal.
- Connect the other end of the positive (+) cable to the generator positive (+) terminal.
- Connect the negative (-) battery cable to the battery negative (-) terminal.
- Connect the other end of the negative (-) cable to the generator negative (-) terminal.
- Start the generator.
Specs & values
- DC terminals may ONLY be used for charging 12 volt automotive-type batteries
Source: Honda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.