Home Generators - Alpha Gen — Filter Removal, Replacement, and Cleaning
For these Home Generators - Alpha Gen models: AlphaGen 3.5kW, AlphaGen 5.0kW, CE3X-2.
Browse Home Generators - Alpha Gen generators & specs →
Procedure
- 1. Unlock and remove the rear door.
- 2. Pull the four captive fasteners (item 1, below) out.
- 3. Tilt the filter frame away from the door and remove the filter.
- 4. Clean the filter using a vacuum or compressed air (if available) to remove loose dust and dirt. Then use a soap and water solution to remove any trapped dirt. Use compressed air to dry the filter. After cleaning, re-coat the filters using RP Super Filter Coat Adhesive, available from local suppliers.
- 5. Replace the filter (Verify the “Air Flow” indicating mark faces into the enclosure) and refasten the filter frame.
- 6. Replace and lock the rear door.
- 3.4 Filter Cleaning 1 1 1 1 Fig. 3-3 Access Panel and Air Filter
- 3. Maintenance 38 031-099-B4-002 Rev. C TM ©2000
- 3.5 PAD SHEAR Magnetic Switch and Water Intrusion Float Allow 15 minutes for completion of procedure Tools required: 3/8”-1/4”-5/16” wrenches Wire cutters Phillips screwdriver
- 1. Remove the APU housing access panel.
Source: manual:3.5kW 5.0kW Operation Maint. Manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.