Home Generators - Alpha Gen — Removal and replacement procedure:
For these Home Generators - Alpha Gen models: AlphaGen 3.5kW, AlphaGen 5.0kW, CE3X-2.
Browse Home Generators - Alpha Gen generators & specs →
Procedure
- 1.
- Remove the APU housing access panel.
- 2.
- Locate and remove the switch and float mounting bracket as shown below.
- Location of bracket mounting nut (3/8”)
- in lower portion of APU housing.
- The pad shear switch and water
- intrusion float bracket is located on the
- outside of the APU housing.
- Remove bracket bolt with a 5/16”
- wrench. Set mounting hardware aside.
- 3. Maintenance
- 38
- 031-099-B4-002 Rev. C
- TM
- ©2000
- 3.5
- PAD SHEAR Magnetic Switch and Water Intrusion Float, contd.
- Cut wires to pad shear sensor. Use
- Phillips screwdriver to remove old
- switch.
- Remove the mounting nuts which
- hold the water intrusion float to the
- bracket. Replace float and verify the
- magnet can slide freely up the
- mounting post, and that it rests
- against the retaining clip at the
- bottom of the mounting post.
- Replace magnetic tamper switch
- with Phillips screwdriver. Splice switch
- wires to original wire harness. Replace
- the mounting bracket to its original
- position on the APU housing.
Source: manual:3.5kW 5.0kW Operation Maint. Manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.