Procedure

  1. Verify all guards and covers are in place and fastened tight.
  2. Check entire machine for loose hardware; tighten all loose hardware.
  3. Fill fuel tank with fuel.
  4. Check engine coolant hoses for damage and loose clamps.
  5. Check engine oil level on dipstick; must be between min and max; add recommended oil if necessary.
  6. Check coolant level in radiator; add coolant to proper level if low.
  7. Check engine and alternator for signs of damage, water, oil or fuel leaks.
  8. Verify intake and outlet air vents and grills are not obstructed or blocked.
  9. Verify there are no obstructions in engine intake air filter tube.
  10. Check fuel filter/water separator for water or contaminants; drain if necessary.
  11. Verify battery cables are properly connected and tight.
  12. Once engine is started, warm engine with a reduced load before applying full load (does not apply to emergency power generators).