Hercules — Illustration No. 16, Item A & B.
A Hercules service procedure — check it applies to your exact model before use.
Browse Hercules generators & specs →
Procedure
- 4. Install mechanical puller on hub of pulley. Puller holes are in
- pulley for this purpose.
- c. Disassembly: Disassemble and inspect crankshaft damper and pulley
- assembly as follows:
- 1. Remove cap screws securing crankshaft damper to pulley.
- 2. Separate the crankshaft damper from the crankshaft pulley assembly.
- 3. Check damper timing mark to be sure they are in perfect alignment
- with timing marks on edge of pulley. See Illustration No. 17. If
- they are not, replace damper, as this indicates that rubber in damper
- is broken or damaged.
- 4, A viscous damper which has no rubber is sometimes used and should be
- inspected regularly and replaced if dented.
Source: manual:HERCULES D4800 Maintenance Manual .pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.