Hercules G-1600 — Voltage Drop Test
Testing & diagnosis · ignition system
For the Hercules G-1600, from the Hercules service manual.
Procedure
- Position the sensor between two trigger wheel teeth.
- Connect voltmeter positive lead to battery positive post and negative lead to coil positive terminal.
- With ignition switch on, voltmeter should read less than one volt, normally about 1/2 volt.
- Flex (wiggle) connections at battery cables, starter solenoid, bulkhead connectors, ammeter terminals, and ignition switch to check for poor circuit conditions.
- Correct any poor connection that causes fluctuation or excessive voltmeter indication.
Tools required
- voltmeter Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Voltage drop less than one volt, normally about 1/2 volt
Source: Hercules service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.